TAILIEUCHUNG - Báo cáo khoa học: "Whole abdomen radiation therapy in ovarian cancers: a comparison between fixed beam and volumetric arc based intensity modulation"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Radiation Oncology cung cấp cho các bạn kiến thức về ngành y đề tài: Whole abdomen radiation therapy in ovarian cancers: a comparison between fixed beam and volumetric arc based intensity modulation. | Mahantshetty et al. Radiation Oncology 2010 5 106 http content 5 1 106 RADIATION ONCOLOGY RESEARCH Open Access Whole abdomen radiation therapy in ovarian cancers a comparison between fixed beam and volumetric arc based intensity modulation 1 1 1 1 1 Umesh Mahantshetty Swamidas Jamema Reena Engineer Deepak Deshpande Rajiv Sarin 2 2 2 2 1 I z- -2 Antonella Fogliata Giorgia Nicolini Alessandro Clivio Eugenio Vanetti Shyamkishore Shrivastava Luca Cozzi Abstract Purpose A study was performed to assess dosimetric characteristics of volumetric modulated arcs RapidArc RA and fixed field intensity modulated therapy IMRT for Whole Abdomen Radiotherapy WAR after ovarian cancer. Methods and Materials Plans for IMRT and RA were optimised for 5 patients prescribing 25 Gy to the whole abdomen PTV_WAR and 45 Gy to the pelvis and pelvic nodes PTV_Pelvis with Simultaneous Integrated Boost SIB technique. Plans were investigated for 6 MV RA6 IMRT6 and 15 MV RA15 IMRT15 photons. Objectives were for both PTVs V90 95 for PTV_Pelvis Dmax 105 for organs at risk maximal sparing was required. The MU and delivery time measured treatment efficiency. Pre-treatment Quality assurance was scored with Gamma Agreement Index GAI with 3 and 3 mm thresholds. Results IMRT and RapidArc resulted comparable for target coverage. For PTV_WAR V90 was and for IMRT6 and IMRT15 and and for RA6 and RA15. Target coverage resulted improved for PTV_Pelvis. Dose homogeneity resulted slightly improved by RA Uniformity was defined as US-9S Ds -D9s Dmean . US-9S for PTV_WAR was and iMrT6 and IMRT15 and RA6 and RA15 for PTV_Pelvis it resulted equal to for all techniques. For organs at risk small differences were observed between the techniques. MU resulted 3130 221 IMRT6 2841 318 IMRT15 538 29 RA6 635 139 RA15 the average measured treatment time was and minutes IMRT6 and IMRT15 and RA6 and RA15 . .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.