TAILIEUCHUNG - METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS

The standard sets out specific requirements for organic production, conversion and natural resource management. The standard includes lists for the allowable inputs for soil management, pest and disease control, and animal health. It also specifies the conditions for processing organic products, such as keeping certified produce separate from conventional produce. Producers must be capable of satisfying the requirements of the standard for at least one year before products can be labelled as organic in-conversion. Producers must then continue to meet the specified requirements for a further two years before being permitted to use the term organic. . | 1151 METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS Scope and Application. Analytes. Analyte CAS No. Volatile Organic Compounds No CAS number assigned VOC Scope. This method is applicable for the determination of VOC leaks from process equipment. These sources include but are not limited to valves flanges and other connections pumps and compressors pressure relief devices process drains open-ended valves pump and compressor seal system degassing vents accumulator vessel vents agitator seals and access door seals. Data Quality Objectives. Adherence to the requirements of this method will enhance the quality of the data obtained from air pollutant sampling methods. Summary of Method. A portable instrument is used to detect VOC leaks from individual sources. The instrument detector type is not specified but it must meet the specifications and performance criteria contained in Section . A leak definition concentration based on a reference compound is specified in each applicable regulation. This method is intended to locate and classify leaks only and is not to be 1152 used as a direct measure of mass emission rate from individual sources. Definitions. Calibration gas means the VOC compound used to adjust the instrument meter reading to a known value. The calibration gas is usually the reference compound at a known concentration approximately equal to the leak definition concentration. Calibration precision means the degree of agreement between measurements of the same known value expressed as the relative percentage of the average difference between the meter readings and the known concentration to the known concentration. Leak definition concentration means the local VOC concentration at the surface of a leak source that indicates that a VOC emission leak is present. The leak definition is an instrument meter reading based on a reference compound. No detectable emission means a local VOC concentration at .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.