TAILIEUCHUNG - báo cáo hóa học:" Development of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions: a technical description"

Tuyển tập các báo cáo nghiên cứu về hóa học được đăng trên tạp chí sinh học quốc tế đề tài : Development of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions: a technical description | Journal of Orthopaedic Surgery and Research Technical Note BioMed Central Open Access Development of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions a technical description John C Janicek William L Carson and David A Wilson Address From the University of Missouri Comparative Orthopaedic Laboratory 379 East Campus Drive Columbia MO 65211 USA Email John C Janicek - jcjanicek@ William L Carson - CarsonWL@ David AWilson - wilsonda@ Corresponding author Published 24 November 2007 Received 21 May 2007 Journal of Orthopaedic Surgery and Research 2007 2 21 doi l749-799X-2-21 Accepted 24 November 2007 This article is available from http content 2 1 21 2007 Janicek et al licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Abstract The purpose of this investigation was to design and verify the capabilities of an in vitro loadingmeasurement system that mimics in vivo unconstrained three dimensional 3D relative motion between long bone ends applies uniform load components over the entire length of a test specimen and measures 3D relative motion between test segment ends to directly determine test segment construct stiffness free of errors due to potting-fixture-test machine finite stiffness. Intact equine cadaveric radius bones which were subsequently osteotomized ostectomized and instrumented with bone plates were subjected to non-destructive axial torsion and 4-point bending loads through fixtures designed to allow unconstrained components of non-load associated 3D relative motion between radius ends. 3D relative motion between ends of a 50 mm long test segment was measured by an infrared optical tracking system to .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.