TAILIEUCHUNG - A Guide to BS EN 62305:2006 Protection Against Lightning Part 6

Các tinh thể băng trong các đám mây có thể là yếu tố quan trọng trong việc hình thành tia sét do nó có thể tạo ra một môi trường tích điện cực trái dấu nhau trong các đám mây dẫn đến việc hình thành sét. | BS EN 62305-3 Physical damage to structures and life hazard If the metallic and electrical services enter the structure at different locations and thus several bonding bars are required these bonding bars should be connected directly to the earth termination system which preferably should be a ring Type B earth electrode arrangement. If a Type A earth electrode arrangement is used then the bonding bars should be connected to an individual earth electrode rod and additionally interconnected by an internal ring conductor. If the services enter the structure above ground level the bonding bars should be connected to a horizontal ring conductor either inside or outside the outer wall and in turn be bonded to the external down conductors and reinforcing bars of the structure. Where structures are typically computer centres or communication buildings where a low induced electromagnetic field is essential then the ring conductors should be bonded to the reinforcing bars approximately every 5 metres. Protection measures for roof mounted equipment containing electrical equipment This is an issue that has already caused some debate. Applying the guidance from BS 6651 the designer installer would bond the metallic roof mounted casing into the mesh air termination system and accept that if the metallic casing suffered a direct lightning strike then the casing if not sufficiently thick could be punctured. What it did not address to any great degree was the solution to the possibility of partial lightning currents or induced overvoltages entering into the structure via any metallic services that were connected to the roof mounted equipment. BS EN 62305-3 significantly elaborates this topic. Our interpretation of the lightning protection requirements can be summarised by the flow chart shown in Figure . There are several scenarios that can occur a If the roof mounted equipment is not protected by the air termination system but can withstand a direct lightning strike without .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.