TAILIEUCHUNG - Power Quality Monitoring Analysis and Enhancement Part 16

Tham khảo tài liệu 'power quality monitoring analysis and enhancement part 16', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 362 Power Quality - Monitoring Analysis and Enhancement Fig. 13. Network after restoration for case 1 Based on the proposed procedure negotiation rules and preset LAs priority list NA first creates the un-served set LA7 LA8 and chooses LA8 as first LA to be restored. LA8 then sends restoration request to its Bus Agent BA4. Since the fault is still there BA4 will send a refuse message to LA8. Thus LA8 tries to restore power from BA3. With 0 available capacities BA3 first negotiates with its connected neighbor BA2 for more power capacity. Because available capacity of BA2 is greater then the request capacity BA2 will transfer to LA8 through BA3. Once LA8 obtains sufficient power it will send a message to NA. NA then deletes LA 8 from un-served set. Next LA7 can also be restored similarly. The communication path is LA7DBA3DBA2. The new network is shown in Figure 13. Case 2 Partial restoration for fault on generator This case will show partial restoration where the amount of available power falls short of the sum of un-served loads. Now the fault happed in one synchronous generator the system then lost one of its major power sources. Figure 14 shows the post fault network. Shaded area has lost power. Like in case 1 the NA first creates un-served set LA1 LA3 LA5 LA7 LA8 . Based on preset priority list LA5 is selected to be first resorted. Through negotiation path LA5DBA1DBA3DBA2 system can not restore LA5 for insufficient available capacity 10 37 . Next LA8 begins the restoration procedure by path LA8DBA4DBA2. After LA8 restoration LA3 can be restored by path LA3DBA1D BA4DBA2. Later LA1 and LA7 fail to obtain power. The amount of available power is only 10. As the total amount of un-served loads is 54 the available power is insufficient to restore all the loads. Although three loads LA1 LA5 LA7 are unfortunately disconnected as shown in the Figure 15 this is the optimal solution under these conditions. 363 Intelligent Techniques and Evolutionary .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.