TAILIEUCHUNG - Atomic Force Microscopy in Cell Biology Episode 2 Part 2

Tham khảo tài liệu 'atomic force microscopy in cell biology episode 2 part 2', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 226 Kiselyova and Yaminsky Fp monomers compare with Fig. 3A . If the two proteins did not interact the histogram of the mixture would be the sum of the two independent ones and would contain two peaks Fig. 3D . But the experimental histogram Fig. 3C shows the third peak located at 6-8 nm corresponding to complexes of cytochrome P450 2B4 and NADPH-cytochrome P450 reductase 2B4 Fp . The molecules of cytochrome P450 Fp and 2B4 Fp are indicated by arrows with respective numbers in Fig. 5. Using the technique described above one can investigate the oligomerization of each of the two proteins in the absence of detergent and qualitatively reveal the dependency of the oligomerization percent versus the protein concentration and buffer ionic strength. AFM image of the oligomers of cytochrome P450 Fig. 6A is apparently similar to that of P450 Fp mixture. Individual monomers within oligomers are not resolved. For the estimation of oligomers percentage one can make height distribution histograms and determine the size of oligomers Fig. 6B Note 7 . Determination of the number of particles in each oligomer requires a geometrical model. The choice of the model depends on the ratio of sizes and a priori knowledge of the molecule properties. 4. Notes 1. If steps are not seen in the image of 10 X 10 pm1 2 3 4 5 either the user is very lucky to have an extremely high quality material or the feedback system of the microscope is not working properly . When using HOPG one has to be careful about artifacts which are now well established 6 7 . 2. Because long contact with the atmosphere contaminates the substrate surface cleavage should be performed right before the application of the sample. Before using a certain substrate for a biological experiment it is strongly recommended to get a few images of it to check for possible defects and artifacts. 3. It is strongly recommended to get several control AFM images of the buffer solution used using the preparation technique described above .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.