TAILIEUCHUNG - Programming manual the Altivar ATV 31

Since it was first marketed, the Altivar ATV 31 has been equipped with additional functions. Software version has now been updated to . This documentation relates to version . | Altivar 31 Programming manual Variable speed drives for asynchronous motors a brand of Schneider Electric Contents Warnings 2 Steps for setting up the starter 3 Factory configuration 4 Software enhancements 5 Basic functions 6 Setup - Preliminary recommendations 8 Functions of the display and the keys 9 Remote terminal option 11 Programming 12 Function compatibility 14 List of functions that can be assigned to inputs outputs 16 List of functions that can be assigned to the CANopen and Modbus control word bits 18 Settings menu SEt-19 Motor control menu drC-23 I O menu I-O-27 Control menu CtL- 31 Application functions menu FUn-42 Fault menu FLt-66 Communication menu COM-70 Display menu SUP- 71 Maintenance 74 Faults - Causes - Remedies 75 Configuration Settings table 77 Index of parameter codes 81 Index of functions 82 NOTE Please also refer to the Installation Guide . 1 Warnings When the drive is powered up the power components and some of the control components are connected to the line supply. It is extremely dangerous to touch them. The drive cover must be kept closed. In general the drive power supply must be disconnected before any operation on either the electrical or mechanical parts of the installation or machine. After the ALTIVAR has been switched off and the display has disappeared completely wait for 10 minutes before working on the equipment. This is the time required for the capacitors to discharge. The motor can be stopped during operation by inhibiting start commands or the speed reference while the drive remains powered up. If personnel safety requires prevention of sudden restarts this electronic locking system is not sufficient fit a cut-off on the power circuit. The drive is fitted with safety devices which in the event of a fault can shut down the drive and consequently the motor. The motor itself may be stopped by a mechanical blockage. Finally voltage variations especially line supply failures can also cause shutdowns. If the cause of the

TÀI LIỆU LIÊN QUAN
TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.