TAILIEUCHUNG - Báo cáo hóa học: " Research Article Iterative Desensitisation of Image Restoration Filters under Wrong PSF and Noise Estimates"

Tham khảo luận văn - đề án 'báo cáo hóa học: " research article iterative desensitisation of image restoration filters under wrong psf and noise estimates"', luận văn - báo cáo phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Hindawi Publishing Corporation EURASIP Journal on Advances in Signal Processing Volume 2007 Article ID 72658 18 pages doi 2007 72658 Research Article Iterative Desensitisation of Image Restoration Filters under Wrong PSF and Noise Estimates Miguel A. Santiago 1 Guillermo Cisneros 1 and Emiliano Bernues2 1 Departamento de Senales Sistemas y Radiocomunicaciones Escuela Tecnica Superior de Ingenieros de Telecomunicacion Universidad Politécnica de Madrid 28040 Madrid Spain 2 Departamento de Ingenieria Electronica y Comunicaciones Centro Politecnico Superior Universidad de Zaragoza 50018 Zaragoza Spain Received 19 July 2005 Revised 30 November 2006 Accepted 3 January 2007 Recommended by Bernard C. Levy The restoration achieved on the basis of a Wiener scheme is an optimum since the restoration filter is the outcome of a minimisation process. Moreover the Wiener restoration approach requires the estimation of some parameters related to the original image and the noise as well as knowledge about the PSF function. However in a real restoration problem we may not possess accurate values of these parameters making results relatively far from the desired optimum. Indeed a desensitisation process is required to decrease this dependency on the parameter errors of the restoration filter. In this paper we present an iterative method to reduce the sensitivity of a general restoration scheme but specified to the Wiener filter with regards to wrong estimates of the said parameters. Within the Fourier transform domain a sensitivity analysis is tackled in depth with the purpose of defining a number of iterations for each frequency element which leads to the aimed desensitisation regardless of the errors on estimates. Experimental computations using meaningful values of parameters are addressed. The proposed technique effectively achieves better results than those obtained when using the same wrong estimates in the Wiener approach as well as verified on an SAR restoration. .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.