TAILIEUCHUNG - Báo cáo khoa học: "Impact of the frequency of online verifications on the patient set-up accuracy and set-up margin"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Radiation Oncology cung cấp cho các bạn kiến thức về ngành y đề tài: Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins. | Rudat et al. Radiation Oncology 2011 6 101 http content 6 1 101 RADIATION ONCOLOGY RESEARCH Open Access Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins 1 11 1 1 2 Volker Rudat Mohamed Hammoud Yogin Pillay Abdul Aziz Alaradi Adel Mohamed and Saleh Altuwaijri Abstract Purpose The purpose of the study was to evaluate the patient set-up error of different anatomical sites to estimate the effect of different frequencies of online verifications on the patient set-up accuracy and to calculate margins to accommodate for the patient set-up error ICRU set-up margin SM . Methods and materials Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy IMRT or three-dimensional conformal radiotherapy 3D-CRT of the head and neck n 31 chest n 72 abdomen n 15 and pelvis n 30 were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes PTV . In 25 patients two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification online verification once a week and online verification every other day. Results The SM could be effectively reduced with increasing frequency of online verifications. However a significant frequency of relevant set-up errors remained even after online verification every other day. For example residual set-up errors larger than 5 mm were observed on average in 18 to 27 of all fractions of patients treated in the chest abdomen and pelvis and in 10 of fractions of patients treated in the head and neck after online verification every other day. Conclusion In patients where high set-up accuracy is desired daily online verification is highly recommended. Introduction Linear accelerators capable

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.