TAILIEUCHUNG - báo cáo khoa học: "Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành y học dành cho các bạn tham khảo đề tài: Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach | Povoski et al. World Journal of Surgical Oncology 2011 9 87 http content 9 1 87 7 WORLD JOURNAL OF SURGICAL ONCOLOGY RESEARCH Open Access Ultrasound-guided diagnostic breast biopsy methodology retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach Stephen P Povoski1 Rafael E Jimenez2 3 and Wenle P Wang2 4 Abstract Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed 724 were by the 8-gauge vacuum-assisted biopsy technique and 719 were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases . benign findings instead of invasive breast carcinoma was significantly greater P in the spring-loaded 14-gauge core biopsy group 8 681 as compared to in the 8-gauge vacuum-assisted biopsy group 0 652 0 with an overall false negative rate of 8 386 for the spring-loaded 14-gauge core biopsy group as compared to 0 0 148 for the 8-gauge vacuum-assisted biopsy group. Significantly more P patients in the spring-loaded 14-gauge core biopsy group 81 719 than in the 8-gauge vacuum-assisted biopsy group 18 724 were

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.