TAILIEUCHUNG - báo cáo hóa học:" Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction"

Tuyển tập các báo cáo nghiên cứu về hóa học được đăng trên tạp chí sinh học quốc tế đề tài : Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction | Anakwe et al. Journal of Orthopaedic Surgery and Research 2010 5 51 http content 5 1 51 JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH RESEARCH ARTICLE Open Access Locked volar plating for complex distal radius fractures Patient reported outcomes and satisfaction RE Anakwe LAK Khan RE Cook JE McEachan Abstract Background Distal radius fractures are common. The increasing prevalence of osteoporosis contributes to frequently complex articular injuries sustained even after low energy falls. The best method of treating complex type C distal radius fractures is debated. Locked volar plating and external fixation are both widely used with good reported results. Measures of success are traditionally based on technical measurements or the perception of the surgeon. Patient reported measures of outcome are increasingly recognised as important markers of surgical success. We report our experience using locked volar plating for complex type C distal radius fractures as well as patient reported measures of success and satisfaction. Methods Over a 12 month period we treated 21 patients with type C distal radius fractures using locked volar plating. These patients were followed up for at least 12 months and the outcome was assessed using clinical examination grip strength measurements radiographs and Patient Rated Wrist Evaluation PRWE scoring. Results The 21 patients studied had an average age of 48 years. There were 8 men and 13 women. All of the fractures had united by 3 months. There were no cases of wound infection or tendon injury irritation. Patients reported low pain scores good patient rated wrist evaluation scores and high levels of satisfaction. Conclusions Locked volar plating for complex distal radius fractures produces good results when assessed using patient reported measures of outcome. Further work should address whether locked volar plating offers superior outcomes and patient satisfaction compared to external fixation. Introduction Distal .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.