TAILIEUCHUNG - báo cáo hóa học:" The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem"

Tuyển tập các báo cáo nghiên cứu về hóa học được đăng trên tạp chí sinh học quốc tế đề tài : The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem | Park et al. Journal of Orthopaedic Surgery and Research 2010 5 40 http content 5 1 40 éHMÌ JOURNAL OF ORTHOPAEDIC oo SURGERY AND RESEARCH RESEARCH ARTICLE Open Access The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem Youngbae Park 41 Carolyne Albert42 Yong-San Yoon 1 Goran Fernlund3 Hanspeter Frei4 and Thomas R Oxland5 Abstract Background In-vitro mechanical tests are commonly performed to assess pre-clinically the effect of implant design on the stability of hip endoprostheses. There is no standard protocol for these tests and the forces applied vary between studies. This study examines the effect of the abductor force with and without application of the anterior-posterior hip contact force in the in-vitro assessment of cementless hip implant stability. Methods Cementless stems VerSys Fiber Metal were implanted in twelve composite femurs which were divided into two groups group 1 N 6 was loaded with the hip contact force only whereas group 2 N 6 was additionally subjected to an abductor force. Both groups were subjected to the same cranial-caudal hip contact force component times body weight BW and each specimen was subjected to three levels of anterior-posterior hip contact load 0 to BW walking and to BW stair climbing . The implant migration and micromotion relative to the femur was measured using a custom-built system comprised of 6 LVDT sensors. Results Substantially higher implant motion was observed when the anterior-posterior force was compared to the lower anterior-posterior load levels particularly distally and in retroversion. The abductor load had little effect on implant motion when simulating walking but resulted in significantly less motion than the hip contact force alone when simulating stair climbing. Conclusions The anterior-posterior component of the hip contact load has a significant effect on the axial .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.