The concept of indoor air quality (IAQ) is not new. Publications as far back as the early 1800s discuss the subject and suggest ventilation as the solution. These early writers mostly recommended a minimum of 5 ft3 /min of outdoor air per person, but later writers increased that number. The present ASHRAE Standard 62 value is 20 ft3 /min for normal situations. | Source HVAC Systems Design Handbook Chapter 21 Indoor Air Quality Background The concept of indoor air quality IAQ is not new. Publications as far back as the early 1800s discuss the subject and suggest ventilation as the solution. These early writers mostly recommended a minimum of 5 ft3 min of outdoor air per person but later writers increased that number. The present ASHrAe Standard 62 value is 20 ft3 min for normal situations. Most of this early work was done in England where a number of public buildings were provided with heating and ventilating systems including the House of Commons. Centrifugal fans were developed using small steam engines for motive power. Schools were a prime target for ventilation and by the early part of the twentieth century the schoolroom unit ventilator was developed and advertised. Electric motors were available by then. A three-story elementary school built in 1916 included an outdoor air-ventilation system with a direct current motor-driven supply fan rheostat control provided manual variable volume and cast iron steam-heating coils in the ventilation air for winter use. When the new science of air cooling came along the value of introducing outdoor air through the cooling heating system was obvious. And as the material in the previous parts of this book shows present technology allows us to control outdoor air ventilation very accurately. But there is a great deal more to improving IAQ than simply using outdoor air. Outdoor air is not necessarily better than indoor air and simple ventilation is not enough. We must also control humidity temperature gaseous particulate bacterial and allergen contaminants as well as air movement within occupied spaces in order to provide a comfortable and healthy environment. 501 Downloaded from Digital Engineering Library @ McGraw-Hill Copyright 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website.

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.