This article introduces high-precision digital potentiometer, optical isolation and self-balancing optical isolation between high and low pressure not only can achieve a complete electrical isolation,but also improve the anti-interference for the system. | Journal of Automation and Control Engineering, Vol. 1, No. 1, March 2013 Study on the Automatic Positioning for Cable Insulation Failure Based on Digital Bridge Method Wu Zhu, Hua-Fu Zhang, Wei-Ya Ma, and Yuan Gui Shanghai University of Electric Power Abstract—To against the problem of the difficult for indentifying the reflected wave of traveling wave and the need of plentiful practical experience and operation skills, this article focuses on designing and developing a digital cable insulation automatic fault locator. The instruments which can locate the fault without the data of length of the cable is based on the principle of HV bridge method and consist of bridge use for measuring cable length and bridge use for locating cable insulation fault. It can automatically improve voltage output of the high-voltage power through constant current detection circuit. To make sure the abilities of high accuracy,stability and fast for this instrument, This article introduces high-precision digital potentiometer, optical isolation and self-balancing optical isolation between high and low pressure not only can achieve a complete electrical isolation,but also improve the anti-interference for the system. needs the cable length of the data with larger transition resistance will affect its accuracy. This study improves from the traditional bridge method such as improve bridge voltage, use multi-tap, high-precision digital potentiometer for self-balancing bridge, it will greatly reduce time for location. II. The overall scheme of the locator system is shown as below, the whole system is composed of high and low voltage bridge structure, low voltage bridge is used for measuring cable length, while high voltage cable is for insulation fault location which needs the length of cable data, through the reed switch to switch the high and low electric bridge. The system mainly includes a high voltage DC source module, a constant current control circuit, bridge zero .

TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.