TAILIEUCHUNG - Electrode wear and material removal rate during EDM of aluminum and mild steel using copper and brass electrodes

(BQ) In the present study an analysis has been done to evaluate the electrode wear along the cross-section of an electrode compared to the same along its length during EDM of aluminum and mild steel using copper and brass electrodes. | Int J Adv Manuf Technol (2008) 39:482–487 DOI ORIGINAL ARTICLE Electrode wear and material removal rate during EDM of aluminum and mild steel using copper and brass electrodes A. A. Khan Received: 19 June 2007 / Revised: 12 September 2007 / Accepted: 12 September 2007 / Published online: 5 October 2007 # Springer-Verlag London Limited 2007 Abstract In the present study an analysis has been done to evaluate the electrode wear along the cross-section of an electrode compared to the same along its length during EDM of aluminum and mild steel using copper and brass electrodes. In an overall performance comparison of copper and brass electrodes, we found that electrode wear increases with an increase in both current and voltage, but wear along the cross-section of the electrode is more compared to the same along its length. This is due to easier heat transfer along the length compared to the same along the crosssection of the electrode. It was also found that the wear ratio increases with an increase in current. That means, though a higher current causes more removal of work material and the electrode, comparatively more material is removed from the electrode. The highest wear ratio was found during machining of steel using a brass electrode. The low thermal conductivity of brass electrodes causes less heat loss, and its low melting point results in fast melting of the electrode material. At the same time, low thermal conductivity of steel results in poor heat absorption, and its high melting temperature causes poor removal of work material. These factors result in the highest wear ratio during machining of steel using a brass electrode. The highest material removal rate was observed during machining of aluminum using brass electrodes. Comparatively low thermal conductivity of brass as an electrode material does not allow the absorption of much heat energy, and most of the heat is utilized in the removal of material from A. A. Khan .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.