TAILIEUCHUNG - Báo cáo " Một kỹ thuật Gam-ma để đo hoạt độ của các thùng chất thải phóng xạ"

Một kỹ thuật Gam-ma để đo hoạt độ của các thùng chất thải phóng xạ Về giá trị KNKH riêng (Bảng 6) cho thấy sự sai khác rõ rệt giữa các dòng tham gia thí nghiệm. KNKH riêng cao nhất khi lai hai dòng IL19 với IL45 đạt 8,28, tiếp đến các cặp dòng VN2 & IL45 đạt 7,27; IL34 & IL45 (5,56). Đặc biệt có dòng IL45 vừa có KNKH chung và KNKH riêng cao, | r TẠP CHÍ KHOA HỌC VÀ CÔNG NGHẸ Tập 46 số 6 2008 Tr. 25-32 A GAMMA TECHNIQUE FOR MEASUMENT OF ACTIVITY OF RADWASTE DRUMS TRAN QUOC DUNG 1. INTRODUCTION The various fuel cycle process results in a considerable amount of radioactive waste which is usually stored in large sealed drums 208 1 . The waste drums must be checked to satisfy regulations of radioactive waste management. The Segmented Gamma Scanning technique SGS is a ti ditional tool used for assay of radioactive waste drums 1 2 The accuracy of the SGS relied on the assumption that the matrix and the sample activity were both homogeneous for a segment. However these assumptions are generally not satisfied when waste or scrap is assayed. Inhomogeneous distribution of radioactive source frequently causes the largest 4 5. In order to increase accuracy some recent methods were proposed technique using two identical detectors 3 6 7 technique utilising multichannel scaling to identify inhomogeneity and to correct results of SGS 8 tomographic techniques 4 9 technique of measuring a segment with different geometry and or some different gamma energy lines of the isotope of interest 10 11 12 . Each technique has its advantages and disadvantages. Choosing a measuring technique depends on concrete situation. This paper presents a technique for determination of gamma activity in waste drums. The basic counting arrangement is similar to the arrangement of SGS but instead of rotating continuously step by step the drum is rotated. The assumptions of this technique are first contract to the assumption of SGS the activity in a segment is concentrated as a point source second the sample matrix is uniform in a segment. In order to evaluate the performance of this method calculations have been carried out based on the mathematical simulation of gamma ray measurement. The calculation results show that the accuracy of this technique is better than that of SGS for most cases where the mixture of activity and matrix is non-uniform. .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.