TAILIEUCHUNG - Báo cáo toán học: " PET kinetics of radiolabeled antidepressant, [N-methyl-11C]mirtazapine, in the human brain"

Tuyển tập các báo cáo nghiên cứu khoa học ngành toán học được đăng trên tạp chí toán học quốc tế đề tài: PET kinetics of radiolabeled antidepressant, [N-methyl-11C]mirtazapine, in the human brain | Munk and Smith EJNMMI Research 2011 1 36 http content 1 1 36 9 EJNMMI Research a SpringerOpen Journal ORIGINAL RESEARCH Open Access PET kinetics of radiolabeled antidepressant N-methyl-11C mirtazapine in the human brain Ole L Munk1 and Donald F Smith2 Abstract Background We compared six kinetic models with and without the requirement of arterial cannulation for estimating the binding potential of N-methyl-11C mirtazapine in the living human brain. Methods Distribution volumes of N-methyl-11C mirtazapine in brain regions were estimated using single- and two-tissue compartment models as well as a graphical plasma input model. The two-tissue compartment model provided a direct estimate of the binding potentials of N-methyl-11C mirtazapine in brain regions while binding potentials of the single-tissue compartment model and the graphical plasma input model were estimated indirectly from ratios of distribution volumes in brain regions. We obtained also direct estimates of binding potentials using a graphical reference tissue model and two nonlinear reference tissue models. Results The two-tissue compartment model required several fits with different initial guesses for avoiding negative values of parameters. Despite the extra fits estimates of distribution volumes and binding potentials of N-methyl-11C mirtazapine obtained by the two-tissue compartment model were far more variable than those produced by the other methods. The graphical plasma input method and the graphical reference tissue method provided estimates of the binding potential that correlated closely but differed in magnitude. The single-tissue compartment model provided relatively low estimates of binding potentials with curves that failed to fit the data as well as the three other methods that used the entire series of positron emission tomography data. The reference tissue method and the simplified reference tissue method provided similar consistent estimates of binding potentials. .

TÀI LIỆU LIÊN QUAN
TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.