TAILIEUCHUNG - HVAC and Dehumidifying Systems_5

Tham khảo tài liệu 'hvac and dehumidifying systems_5', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | MIL-HDBK-1003 3 Simpo PDF Merge and Split Unregistered Version - http Reprinted by permission of ASHRAE from ASHRAE Handbook Fundamentals. Figure 13 Friction Loss for Water in Plastic Pipe Schedule 80 a Hot Water Piping to Coil. Water coils will not perform if there is air in the piping. Ensure that the piping from the main to the coil and to the return main is appropriately sloped up and vented to eliminate entrained air that can air lock the flow. b Hot Water Coil Selection. Consult the manufacturer s catalog data to decide the best selection number of rows parallel or counter flow turbulators or serpentines and other selection information. Using the appropriate type make the coil selection 1 Capacity required 2 Water temperature in and out 3 Air temperature in and out 4 Airflow 5 Water flow 6 Air pressure drop 72 Simpo PDF Merge and Split UnregisteredVersion- http 7 Water pressure drop 8 Coil face velocity 9 Any special requirements After the coil selection has been made and documented in the design analysis be sure to provide the above data in the coil schedule on drawings. This will ensure a good bidding climate with equipment manufacturers knowing what to bid and what to submit in the shop drawings phase. Expansion Tanks and Air Separator a Expansion Tanks General. When water in a hot water heating system is heated water expands and occupies more volume. System pressure control is needed to 1 Limit pressure in all parts of the system to the allowable working pressure. 2 Maintain minimum pressure in the system to prevent pump cavitation and to prevent boiling of system water. 3 Minimize addition of makeup water. b Expansion Tank With Air Separator. An expansion tank with an air separator performs these system pressure control functions. Since this section does not address medium temperature hot water system 250 to 350 degrees F or high temperature hot water system above 350 degrees F discussion will be limited to the .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.