TAILIEUCHUNG - Báo cáo khoa học: " Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Radiation Oncology cung cấp cho các bạn kiến thức về ngành y đề tài: " Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma. | BioMed Central Radiation Oncology Research Open Access Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma Barbara Dobler Fabian Pohl Ludwig Bogner and Oliver Koelbl Address Department of Radiotherapy University of Regensburg Regensburg Germany Email Barbara Dobler - Fabian Pohl - Ludwig Bogner - Oliver Koelbl - Corresponding author Published 6 September 2007 Received 3 June 2007 Radiation Oncology 2007 2 33 doi 1748-717X-2-33 Accepted 6 September 2007 This article is available from http content 2 1 33 2007 Dobler et al licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Abstract Background To evaluate the effects of direct machine parameter optimization in the treatment planning of intensity-modulated radiation therapy IMRT for hypopharyngeal cancer as compared to subsequent leaf sequencing in Oncentra Masterplan . Methods For 10 hypopharyngeal cancer patients IMRT plans were generated in Oncentra Masterplan Nucletron BV Veenendal the Netherlands for a Siemens Primus linear accelerator. For optimization the dose volume objectives DVO for the planning target volume PTV were set to 53 Gy minimum dose and 59 Gy maximum dose in order to reach a dose of 56 Gy to the average of the PTV. For the parotids a median dose of 22 Gy was allowed and for the spinal cord a maximum dose of 35 Gy. The maximum DVO to the external contour of the patient was set to 59 Gy. The treatment plans were optimized with the direct machine parameter optimization Direct Step Shoot

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.