TAILIEUCHUNG - Báo cáo khoa học: " Dosimetric accuracy of tomotherapy dose calculation in thorax lesions"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Radiation Oncology cung cấp cho các bạn kiến thức về ngành y đề tài: Dosimetric accuracy of tomotherapy dose calculation in thorax lesions. | Ardu et al. Radiation Oncology 2011 6 14 http content 6 1 14 RADIATION ONCOLOGY RESEARCH Open Access Dosimetric accuracy of tomotherapy dose calculation in thorax lesions Veronica Ardu Sara Broggi Giovanni Mauro Cattaneo Paola Mangili Riccardo Calandrino Abstract Background To analyse limits and capabilities in dose calculation of collapsed-cone-convolution CCC algorithm implemented in helical tomotherapy HT treatment planning system for thorax lesions. Methods The agreement between measured and calculated dose was verified both in homogeneous Cheese Phantom and in a custom-made inhomogeneous phantom. The inhomogeneous phantom was employed to mimic a patient s thorax region with lung density encountered in extreme cases and acrylic inserts of various dimensions and positions inside the lung cavity. For both phantoms different lung treatment plans single or multiple metastases and targets in the mediastinum using HT technique were simulated and verified. Point and planar dose measurements both with radiographic extended-dose-range EDR2 and radiochromic external-beamtherapy EBT2 films were performed. Absolute point dose measurements dose profile comparisons and quantitative analysis of gamma function distributions were analyzed. Results An excellent agreement between measured and calculated dose distributions was found in homogeneous media both for point and planar dose measurements. Absolute dose deviations 3 were found for all considered measurement points both inside the PTV and in critical structures. Very good results were also found for planar dose distribution comparisons where at least 96 of all points satisfied the gamma acceptance criteria 3 -3 mm both for EDR2 and for EBT2 films. Acceptable results were also reported for the inhomogeneous phantom. Similar point dose deviations were found with slightly worse agreement for the planar dose distribution comparison 96 of all points passed the gamma analysis test with acceptable levels of 4 -4

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.