TAILIEUCHUNG - báo cáo hóa học:" Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation"

Tuyển tập các báo cáo nghiên cứu về hóa học được đăng trên tạp chí sinh học quốc tế đề tài : Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation | Journal of Orthopaedic Surgery and Research BioMed Central Open Access Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation George K Kouvidis 1 Mark B Sommers2 Peter V Giannoudis3 Pavlos G Katonis1 and Michael Bottlang2 Address Department of Orthopaedic Surgery and Traumatology University Of Crete Heraklion Greece 2Biomechanics Laboratory Legacy Research Technology Center Portland Oregon 97215 USA and 3Trauma Orthopaedic Surgery School Of Medicine University of Leeds Leeds General Infirmary Great George Street Leeds LSI 3EX UK Email George K Kouvidis - kouvidisgeo@ Mark B Sommers - msommers@ Peter V Giannoudis - pgiannoudi@ Pavlos G Katonis - katonis@ Michael Bottlang - mbottlang@ Corresponding author Published 18 May 2009 Received 23 November 2008 Journal of Orthopaedic Surgery and Research 2009 4 16 doi l749-799X-4-l 6 Accepted 18 May 2009 This article is available from http content 4 l 16 2009 Kouvidis et al licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Abstract Background Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. Methods Five dual lag screw implants Endovis Citieffe and five single lag screw implants DHS Synthes were tested in the Hip .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.