TAILIEUCHUNG - Bioluminescence Recent Advances in Oceanic Measurements and Laboratory Applications Part 13

Tham khảo tài liệu 'bioluminescence recent advances in oceanic measurements and laboratory applications part 13', khoa học tự nhiên, công nghệ sinh học phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Oscillation in Bacterial Bioluminescence 171 optical density meter solar cell A 500 mL Erlenmeyer flask with 100 mL oscillation broth was shaken at 100 rpm. Solar cells were attached on the flask surface. All the optical setup was enclosed in a self-made dark box. Fig. 3. Experimental setup for the simultaneous measurement of the luminescence and cell density. Spectral change in the bacterial bioluminescence during oscillation Two optical filters that transmit wavelengths of 479 and 521 nm Optical Coatings Japan were placed to cover the sensor windows of the optical power meter Fig. 3 . 172 Bioluminescence - Recent Advances in Oceanic Measurements and Laboratory Applications Two sensors with filters were placed at the same height so that the stirrer bar did not affect the measurement. All the optical setup including the magnetic stirrer was enclosed in the incubator. Fig. 4. System setup for the measurement of spectral change. 3. Results and discussion The effects of the suspension volume on the oscillation mode are shown in Fig. 5. Remarkable oscillatory waves were observed in the case of 10 20 and 30 mL but not in the case of 50 mL. It was noteworthy that even with the largest volume the 50 mL suspension showed the smallest luminescent intensity. This might be due to the shortage of the oxygen supply as the fixed liquid-air interface area could allow a fixed amount of oxygen diffusion into the suspension. In the case of 50 mL the distributed oxygen to each cell should be smaller than in the case of other volumes. As the case of 30 mL showed the most distinct oscillation this volume was chosen for further experiments. Oscillation in Bacterial Bioluminescence 173 P. kishitanii was inoculated into oscillation broth with each volume in a 22 mm diameter glass tube. The suspension was stirred using a magnetic stirrer. The temperature was maintained at 17 C. Fig. 5. Suspension volume effect on the oscillation in bacterial bioluminescence. First oscillation in .

TÀI LIỆU LIÊN QUAN
TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.