TAILIEUCHUNG - FLAME SAFEGUARn CONTRULS phần 4

Cam TIMER có thể được thêm (Hình 36) Thêm ce trên lh9 khung lập trình cho phép cam được thêm 10 lh9 timet wifhout redeslgt ThI6 có thể cần thiết Nếu địa chỉ liên lạc hẹn giờ mEleI tương lai | When the operator pushes and holds in the START button on the S445A. power is fed from terminal 8 through the START switch to the ignition it also goes from terminal 8 through the internal jumper of the S445A the STOP switch trie high limit and the Jumper from terminal 6 to terminal 4 to the burner motor and pilot valve. The pilot should ignite. Power is atso fed to the IK relay coil terminal 6J. Relay 1K pulls In. Contact 1K1 opens de-energizing the alarm terminal 3 . Contact 1K2 closes bypassing the safe start contact 2K1 and 1K3 closes. When the pilot ignites and the flame is detected the flame relay 2K pulls In. Contact 2K2 closes bypassing the START switch the operator can now release the START button. Contact 2K3 closes energizing terminal 7 through contact 1K3. The main valve s should open and the main burner should ignite. The system is now in the run condition with the main burner firing. If the flame goes out the flame relay 2K drops out. Contacts 2K2 and 2K3 open de-energizing terminals 5 6 4 and 7. The burner motor pilot valve and main valve sj are de-energized. Relay IK drops out and contact 1K1 closes RA890 PRIMARY CONTROLS energizing the alarm terminal 3 . The R485 does not recycle on flame failure. For normal shutdown the operator pushes the STOP button on the S445A removing power from terminals 6 4 and 7. Relay 1K lhe burner motor the pilot valve and the main vaive s are de-energized. The burner is shut down. In summary the R7023 consists simply of a flame detection network and a relay. When flame is detected the relay SPDT or OPDT pulls in. When flame is not detected the relay drops out. The relay has no built-in safety features. The R485 adds a load relay to the R7023-and with it the ability to perform a safe start check and burner sequencing on manual or semiautomatic start systems. The following sections will cover in detail the application and operation of the RAB90 R4795 and R7795 primary controls. The RA890 controls use the same basic .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.