TAILIEUCHUNG - KRONE - Datasheet - Cat 6 - Cable - S-STP 450MHz FRNC 1000m reel

The KRONE S-STP 450/AWG23 cable is designed for applications up to 450 MHz and provides transmission performance meeting Category 6 specifications. This cables are low skew products, . the difference in propagation delay between the individual pairs is very low. | 2 3 Installation Cable - S-STP 450 AWG23 FRNC - Duplex S-STP 450 AWG23 FRNC UJ Application The KRONE S-STP 450 AWG23 cable is designed for applications up to 450 MHz and provides transmission performance meeting Category 6 specifications. This cables are low skew products . the difference in propagation delay between the individual pairs is very low. This is increasingly being requested for Gigabit Ethernet. The suitability of the cable for high-bit-rate transmission systems ensures a high degree of future proofing. Additional features are the slim design and low weight of the cables. Each pair is individually shielded STP . The twisted pairs are additionally enclosed as a group in a braided shield S-STP to provide superior shielding performance. The cable thus exceeds the requirements for EN 55022 Class B emission and EN 55024 immunity enabling networks to be built which are compliant with the standards on electromagnetic compatibility. Copper Conductor AWG 23 Foam Skin-PE-insulation Foil shield Twisted pair Braided shield 4 twisted pairs Sheath zero halogen flame retardant S-STP 450 AWG23 4P Characteristics The KRONE S-STP 450 AWG23 cables are available in halogenfree versions with FRNC outer jacket. Every single pair is shielded with foil STP . Each pair is individually shielded STP . The twisted pairs are additionally enclosed as a group in a braided shield S-STP to provide superior shielding performance. This cables are low skew products . the difference in propagation delay between the individual pairs is very low. The slim and lightweight design allowed best characteristics in fire retardance. The compact design allows the cables to be installed flat or folded together. Print example single cable KRONE PREMISNET CAT6 S-STP LSZH FR 4P AWG23 SBC ISO IEC 11801 EN50173-1 IEC 60332-3 CAT C Woche Jahr CA KRONE 7053326255 METERMARKER Charge Duplex cable same as single cable except for part number. KRONE GmbH Beeskowdamm 3-11 14167 Berlin Tel. 49 30 84 .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.