TAILIEUCHUNG - Lecture Methods of Electric power systems analysis - Lesson 3: Per unit, Ybus, power flow

Lecture Methods of Electric power systems analysis - Lesson 3: Per unit, Ybus, power flow provide students with knowledge about wind now surpasses nuclear and hydro; slowing electric load growth; interconnected power system basic characteristics; three-phase per unit; | ECEN 615 Methods of Electric Power Systems Analysis Lecture 3 Per Unit Ybus Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering Texas A amp M University overbye@ Announcements Start reading Chapters 1 to 3 from the book mostly background material Homework 1 is assigned today. It is due on Thursday September 3 Public website is ecen-615-fall-2020 1 Wind now surpasses nuclear and hydro Source electricity monthly update April 2020 2 Slowing Electric Load Growth Much of the slowing load growth is due to distributed generation such as solar PV which sits on the customer side of the meter Source EIA Monthly Energy Review July 2019 3 Except in Texas The left graph is peak demand the right energy ERCOT set a new peak electric load of GW on 8 12 19 surpassing the GW record from 2018 total energy in 2017 was 357 billion kWh Source gridinfo load forecast 4 Interconnected Power System Basic Characteristics Three phase AC systems generation and transmission equipment is usually three phase industrial loads are three phase residential and commercial loads are single phase and distributed equally among the phases consequently a balanced three phase system results Synchronous machines generate electricity Exceptions some wind is induction generators solar PV Interconnection transmits power over a wider region with subsystems operating at different voltage levels 5 Load Models Omitted from Lecture 2 Ultimate goal is to supply loads with electricity at constant frequency and voltage Electrical characteristics of individual loads matter but usually they can only be estimated actual loads are constantly changing consisting of a large number of individual devices only limited network observability of load characteristics Aggregate models are typically used for analysis Two common models The ZIP model combines constant constant power Si Pi jQi impedance current constant impedance Si V 2 Zi and power

TỪ KHÓA LIÊN QUAN
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.