TAILIEUCHUNG - Prototyping of dssds for particle tracking and spectroscopy within the exl project at fair

The response of these detectors for 241Am α particles injected either from the p or n side was examined. The test measurements were performed partially at GSI and the University of Edinburgh. A first in-beam test with a proton beam of 50 MeV with the latter two DSSDs and two mm thick Si(Li) detectors was also done at KVI Groningen, the Netherlands. The results reveal good spectroscopic properties of these detectors. | Communications in Physics, Vol. 22, No. 3 (2012), pp. 263-273 PROTOTYPING OF DSSDS FOR PARTICLE TRACKING AND SPECTROSCOPY WITHIN THE EXL PROJECT AT FAIR L. X. CHUNG Institute for Nuclear Science and Technology and GSI, Helmholtzzentrum f¨ ur Schwerionenforschung GmbH, Darmstadt, Germany N. T. KHAI Institute for Nuclear Science and Technology P. EGELHOF, S. ILIEVA, AND B. STREICHER GSI, Helmholtzzentrum f¨ ur Schwerionenforschung GmbH, Darmstadt, Germany R. BORGER, C. RIGOLLET, N. KALANTAR-NAYESTANAKI, AND A. NAJAFI KVI, University of Groningen, the Netherlands T. DAVINSON AND P. J. WOODS University of Edinburgh, United Kingdom V. EREMIN PTI, Ioffe Physical Technical Institute of Russian Academy of Sciences, St. Petersburg, Russia M. MUTTERER GSI, Helmholtzzentrum f¨ ur Schwerionenforschung GmbH, Darmstadt, Germany and Institut f¨ ur Kernphysik, Technische Universit¨ at Darmstadt, Darmstadt, Germany M. VON SCHMID Institut f¨ ur Kernphysik, Technische Universit¨ at Darmstadt, Darmstadt, Germany Abstract. Prototype double-sided silicon strip detectors (DSSDs) of 300 µm thickness produced at PTI St. Petersburg (Russia) were tested for the use as position sensitive, ∆E and E detectors for tracking and particle identification in the EXL (EXotic nuclei studied in Light-ion induced reactions at the NESR storage ring) setup at the FAIR (Facility for Antiproton and Ion Research) project at GSI. We describe the characteristics of detectors with 16×16, 64×64 and 64×16 strips, respectively. The response of these detectors for 241 Am α particles injected either from the p or n side was examined. The test measurements were performed partially at GSI and the University of Edinburgh. A first in-beam test with a proton beam of 50 MeV with the latter two DSSDs and two mm thick Si(Li) detectors was also done at KVI Groningen, the Netherlands. The results reveal good spectroscopic properties of these detectors. 264 PROTOTYPING OF DSSDs FOR PARTICLE TRACKING AND SPECTROSCOPY .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.