TAILIEUCHUNG - báo cáo khoa học: "Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành y học dành cho các bạn tham khảo đề tài: Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor | Journal of NeuroEngineering and Rehabilitation BioMed Central Open Access Ambulatory measurement of knee motion and physical activity preliminary evaluation of a smart activity monitor James Huddleston 1 3 Amer Alaiti2 Dov Goldvasser2 Donna Scarborough2 Andrew Freiberg1 Harry Rubash1 Henrik Malchau1 William Harris1 and David Krebs2 Address 1Harvard Medical School Harris Orthopaedic Biomechanics and Biomaterials Laboratory Massachusetts General Hospital 55 Fruit Street GRJ 1126 Boston MA 02114-2696 2Harvard Medical School Massachusetts General Hospital Biomotion Laboratory MGH Institute of Health Professionals Charlestown Navy Yard 36 First Avenue 223 Boston MA 02129-4557 and 3Department of Orthopaedic Surgery Stanford University School of Medicine 300 Pasteur Drive R-105 Stanford CA 94305-5341 Email James Huddleston - jhuddleston@ Amer Alaiti - aalaiti@ Dov Goldvasser - dgoldvasser@ Donna Scarborough - dscarborough@ Andrew Freiberg - afreiberg@ Harry Rubash - hrubash@ Henrik Malchau - hmalchau@ William Harris - David Krebs - dkrebs@ Corresponding author Published 13 September 2006 Received 17 June 2005 Journal of NeuroEngineering and Rehabilitation 2006 3 21 doi l743-0003-3-2l Accepted 13 September 2006 This article is available from http content 3 l 2l 2006 Huddleston et al licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Abstract Background There is currently a paucity of devices available for continuous long-term monitoring of human joint motion. Non-invasive inexpensive devices capable of recording human activity and joint motion have many applications for medical .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.