TAILIEUCHUNG - Báo cáo y học: "Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học General Psychiatry cung cấp cho các bạn kiến thức về ngành y đề tài: Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound. | Klauser et al. Arthritis Research Therapy 2010 12 R209 http content 12 6 R209 RESEARCH ARTICLE Open Access Detection of vascularity in wrist tenosynovitis power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound 1 13 1 2 2 Andrea S Klauser Magdalena Franz Rohit Arora Gudrun M Feuchtner Johann Gruber Michael Schirmer Werner R Jaschke1 Markus F Gabl3 Abstract Introduction We sought to assess vascularity in wrist tenosynovitis by using power Doppler ultrasound PDUS and to compare detection of intra- and peritendinous vascularity with that of contrast-enhanced grey-scale ultrasound CEUS . Methods Twenty-six tendons of 24 patients nine men 15 women mean age SD years with a clinical diagnosis of tenosynovitis were examined with B-mode ultrasonography PDUS and CEUS by using a second-generation contrast agent SonoVue Bracco Diagnostics Milan Italy and a low-mechanical-index ultrasound technique. Thickness of synovitis extent of vascularized pannus intensity of peritendinous vascularisation and detection of intratendinous vessels was incorporated in a 3-score grading system grade 0 to 2 . Interobserver variability was calculated. Results With CEUS a significantly greater extent of vascularity could be detected than by using PDUS P . In terms of peri- and intratendinous vessels CEUS was significantly more sensitive in the detection of vascularization compared with PDUS P . No significant correlation between synovial thickening and extent of vascularity could be found P to . Interobserver reliability was calculated to be excellent when evaluating the grading score k to . Conclusions CEUS is a promising tool to detect tendon vascularity with higher sensitivity than PDUS by improved detection of intra- and peritendinous vascularity. Introduction Besides mechanical overloading and attrition rheumato-logic diseases are widespread causes of tenosynovitis and tendinosis. These chronic systemic

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.