TAILIEUCHUNG - The ICU and hemodynamic monitoring: Part 2

(BQ) Continued part 1, part 2 of the document The ICU and hemodynamic monitoring has contents: Hemodynamic monitoring techniques, monitoring the adequacy of oxygen supply and demand, echocardiography, preload dependency dynamic indices, perspectives Invite you to refer. | Hemodynamic Monitoring Techniques 3 Measurement of Pulmonary Artery Occlusion Pressure by the Pulmonary Artery Catheter Principle Pulmonary arterial pressure PAP is measured at the distal end of the Swan-Ganz catheter. A transient occlusion of blood flow is performed during inflation of the distal balloon in a large caliber pulmonary artery. Beyond the balloon the pressure drops in the pulmonary artery to a pressure called the pulmonary artery occlusion pressure PAOP Fig. . This pressure is the same throughout the pulmonary vascular segment in which the balloon is occluded. This segment behaves as an open downstream static column of blood in the pulmonary venous segment. In this regard the PAOP is a reflection of the pulmonary venous pressure. Because the artery occluded by the balloon is rather large in size the PAOP is the pressure of a pulmonary vein of the same caliber. Because the resistance of the pulmonary venous segment flowing into the left atrium is considered to be low the PAOP is a good reflection of the pressure of the left atrium and by extension the diastolic pressure of the left ventricle provided that there is no mitral stenosis. Notably the PAOP does not match the pulmonary artery wedge pressure. The wedge pressure corresponds to the pressure in relation to the occlusion of a pulmonary vessel of a smaller caliber obtained without inflating the balloon. Thus the wedge pressure reflects the pulmonary venous pressure in an area with a lower rating and is greater than the PAOP. Finally the pulmonary capillary pressure cannot be directly measured. It can only be estimated in two ways from the decay curve upon balloon inflation or from the Gaar equation as follows Pulmonary capillary pressure PAOP PA . - PAOP Unfortunately this formula is only relevant if the venous resistance is homogeneously distributed. Pulmonary capillary pressure is rarely used in clinical practice due to the difficulty of measurement even though it reliably .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.