Đang chuẩn bị liên kết để tải về tài liệu:
Intelligent and Biosensors 2012 Part 9

Đang chuẩn bị nút TẢI XUỐNG, xin hãy chờ

Tham khảo tài liệu 'intelligent and biosensors 2012 part 9', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Mercaptobenzothiazole-on-Gold Organic Phase Biosensor Systems 3. Thick-Film Biosensors for Organophosphate and Carbamate Pesticide Determination 191 was added to the Au MBT PANI AChE PVAc biosensor Albareda-Sirvent et al. 2001 Pritchard et al. 2004 Bucur et al. 2005 Somerset et al. 2009 . 2.11 Long-term stability investigation of Au MBT PANI AChE biosensor The operation of the Au MBT PANI AChE PVAc biosensor was evaluated at different time intervals of 7 day periods for a total of 30 days using one specific biosensor. A 1 ml test solution containing 0.1 M phosphate buffer 0.1 M KCl solution was degassed with argon before any substrate was added. The Au MBT PANI AChE PVAc biosensor was then evaluated in the 1 ml test solution with small aliquots of the substrate consisting of 0.01 M acetylthiocholine ATCh being added to the test solution followed by degassing. The maximum current response of the biosensor was then obtained after 2 mM of the ATCh substrate was added to the Au MBT PANI AChE PVAc biosensor. This procedure was performed on 0 7 14 21 and 28 days using one specific Au MBT PANI AChE PVAc biosensor Albareda-Sirvent et al. 2001 Somerset et al. 2009 . 2.12 Temperature stability investigation of Au MBT PANI AChE biosensor The temperature stability of the Au MBT PANI AChE PVAc biosensor was evaluated at different temperature values. To achieve this the optimum temperature for AChE activity in the constructed biosensor was determined by assaying the biosensor at various temperatures of 10 15 20 25 30 and 35 C. A 1 ml test solution containing 0.1 M phosphate buffer 0.1 M KCl solution was degassed with argon before any substrate was added and incubated in a small water bath for approximately 10 minutes at a specific temperature. The Au MBT PANI AChE PVAc biosensor was then evaluated in the 1 ml test solution with small aliquots of the substrate consisting of 0.01 M acetylthiocholine ATCh being added to the test solution followed by degassing. The maximum current .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.