Đang chuẩn bị nút TẢI XUỐNG, xin hãy chờ
Tải xuống
Studies on quantitative fit analysis of precontoured fracture fixation plates emerged within the last few years and therefore, there is a wide research gap in this area. Quantitative fit assessment facilitates the measure of the gap between a fracture fixation plate and the underlying bone, and specifies the required plate fit criteria. For clinicallymeaningful fit assessment outcome, it is necessary to establish the appropriate criteria and parameter. The present paper studies this subject and recommends using multiple fit criteria and the maximum distance between the plate and underlying bone as fit parameter for clinically relevant outcome. | This is an open-access article distributed under the terms of the Creative Commons Attribution License which. permits unrestricted use distribution and reproduction ỉn any medium provided the originalauthor s and source are credited. ISSN 1662-100X Biomimetics Biomaterials and I issue Engineering The International Open Access Biomimetics Biomaterials and Tissue Engineering Executive Editors Andrew J Ruys University of Sydney Australia Mei Wei University of Connecticut USA Min Wang The Univeristy of Hong Kong Hong Kong Available online at OMICS Publishing Group www.omicsonline.org This article was originally published in a journal by OMICS Publishing Group and the attached copy is provided by OMICS Publishing Group for the author s benefit and for the benefit of the author s institution for commercial research educational use including without limitation use in instruction at your institution sending it to specific colleagues that you know and providing a copy to your institution s administrator. All other uses reproduction and distribution including without limitation commercial reprints selling or licensing copies or access or posting on open internet sites your personal or institution s website or repository are requested to cite properly. Digital Object Identifier http dx.doi.org 10.4172 1662-100X.1000116 Biomimetics Biomaterials and Tissue Engineering Review Article Harith et al. J Biomim Biomater Tissue Eng 2013 18 2 http dx.doi.org 10.4172 1662-100X.1000116 Open Access Quantitative Fit Analysis of Orthopedic Bone Plates Methods Criteria and Approach Hazreen Harith Javad Malekani Beat Schmutz Michael Schuetz and Prasad KDV Yarlagadda Science and Engineering Faculty Queensland University of Technology QUT Australia Abstract Studies on quantitative fit analysis of precontoured fracture fixation plates emerged within the last few years and therefore there is a wide research gap in this area. Quantitative fit assessment facilitates the measure of the gap between a