Đang chuẩn bị liên kết để tải về tài liệu:
Transformer Engineering - Design and Practice Episode 1

Đang chuẩn bị nút TẢI XUỐNG, xin hãy chờ

Tham khảo tài liệu 'transformer engineering - design and practice episode 1', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Appendix A Fault Calculations In this appendix asymmetrical fault calculations for a transformer are given. A single-line-to-ground fault on LV side is considered. The neutrals of LV and HV windings are solidly grounded. Two distinct cases are considered viz. with and without fault in-feed from the secondary LV side. For each of these two cases two conditions are considered viz. with and without stabilizing tertiary winding TV . The effects of omitting tertiary winding are illustrated with these cases. Transformer Data Rating S 25 MVA Core construction three-phase three-limb Voltage ratio HV LV TV 132 11 11 KV star star delta Leakage sequence impedances based on 25 MVA base HV LV Z1 Z2 12 Z0 10.2 HV TV Z1 Z2 20 Zo 17.0 LV TV Z1 Z2 6 Zo 5.4 132 KV system fault level SF 5000 MVA The positive-sequence system impedance on the HV side is Z1HS 0.5 calculated by equation 6.2 . The HV and LV side systems are assumed as effectively grounded systems Xfj Xx not greater than 3 . Here in particular the zero-sequence system impedances on the LV and HV sides are assumed to be equal to the corresponding positive-sequence system impedances for simplicity. As mentioned earlier two alternatives are considered for 11 KV LV system i Without any fault in-feed from 11 KV system. ii With fault in-feed from 11 KV system 453 Copyright 2004 by Marcel Dekker Inc. 454 Appendix A 11 KV system fault level SF 833.33 MVA which gives the positivesequence system impedance on LV side Z1LS 3.0 by equation 6.2 . The equivalent impedances in the star equivalent circuit can be computed by using the theory given in Section 3.5 Chapter 3 as ZH ZHL ZHT-ZLT 2 ZL ZHL ZLT-ZHT 2 ZT ZHT ZLT-ZHL 2 Therefore the corresponding positive- negative- and zero-sequence impedances of HV LV and TV windings are computed as follows Z1H Z2H 12 20-6 2 l3 ZOh 10.2 17-5.4 2 10.9 Z1L Z2L 12 6-20 2 -l Zol 10.2 5.4-17 2 -0.7 Z1T Z2T 20 6-12 2 7 ZOt 17 5.4-10.2 2 6.1 0.5 13 -1 -mm--------ƠĨT----------mm- Positive-sequence network .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.