Đang chuẩn bị liên kết để tải về tài liệu:
Báo cáo khoa học: "Safety margin in irradiation of colorectal liver metastases: assessment of the control dose of micrometastases"

Đang chuẩn bị nút TẢI XUỐNG, xin hãy chờ

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Radiation Oncology cung cấp cho các bạn kiến thức về ngành y đề tài: Safety margin in irradiation of colorectal liver metastases: assessment of the control dose of micrometastases. | Seidensticker et al. Radiation Oncology 2010 5 24 http www.ro-journal.eom content 5 1 24 RADIATION ONCOLOGY RESEARCH Open Access Safety margin in irradiation of colorectal liver metastases assessment of the control dose of micrometastases Max Seidensticker 1 Peter Wust2 Ricarda Ruhl1 Konrad Mohnike1 Maciej Pech1 Gero Wieners1 Gunther Gademann3 and Jens Ricke1 Abstract Backround Micrometastases of colorectal liver metastases are present in up to 50 of lesions. In this study we sought to determine the threshold dose for local control of occult micrometastases in patients undergoing CT computed tomography -guided brachytherapy of colorectal liver metastases. Materials and methods Nineteen patients demonstrated 34 local tumor recurrences originating from micrometastases after CT-guided brachytherapy of 27 colorectal liver metastases. We considered a local tumor recurrence as originating from a micrometastasis if tumor regrowth occurred adjacent to a formerly irradiated lesion and the distance of the 3D isocenter of the new lesion was 23.5 mm from the previous tumor margin. Follow-up MRI was fused with the planning-CT and dosimetry data. Two reviewers independently indicated the dose exposure at the isocenter of the micrometastases. Statistical analysis included an analysis of variance ANOVA using backward selection. 95 tolerance intervals with coverage of 87.5 and 75 of the data of the normal distribution were calculated. Results The median distance of the micrometastases to the margin of the originating colorectal metastases was 8.75 mm 1-21 mm . Dose exposure at the isocenter was 12.25 Gy 7-19.8 in median. We stratified according to the distance from the isocenter to the initial tumor margin 9 mm 9-15 mm and 15 mm. The median dose in the according isocenters was 13.18 11.6 and 11.85 Gy. The threshold dose failing to prevent micrometastasis growth was sigificantly higher in a subgroup of lesions with 9 mm distance as compared to 15 mm 13.18 vs 11.85 Gy . Adjuvant .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.