Đang chuẩn bị liên kết để tải về tài liệu:
The slitlamp primer - part 2

Đang chuẩn bị nút TẢI XUỐNG, xin hãy chờ

và ánh sáng được phối hợp để cấu trúc được xem là phóng đại và chiếu sáng. Điều này có thể được thay đổi bằng cách di chuyển hình ảnh khe ra khỏi trung tâm, như là yêu cầu của một số kỹ thuật chiếu sáng (thảo luận trong chương 4). Trong khi ánh sáng trắng được sử dụng cho hầu hết các kỳ thi | 4 Chapter 1 Figure 1-3A. Magnification may be changed by flipping a lever. Photo by Mark Arrigoni. Figure 1-3B.or rotating a knob. Reprinted with permission from Ophthalmic Photography SLACK Incorporated. Figure 1-4B. .or levers Reprinted with permission from Oph- thalmic Photography SLACK Incorporated. Photo by Steve Carlton. The Slit Lamp 5 Figure 1-5. The angle of the light source is indicated by a dial at the base of the arm. Photo by Val Sanders. and light are coordinated so that the structure to be viewed is magnified and illuminated. This can be altered by moving the slit image off center as is required by some illumination techniques discussed in Chapter 4 . While white light is used for most examinations there are several colored filters that can be utilized as well. The cobalt blue filter is used in conjunction with fluorescein dye. The dye pools in areas where the corneal epithelium is broken or absent. The blue light excites the fluorescein which then takes on a yellowish glow. The green filter obscures anything that is red hence the pseudonym red-free light thus blood vessels or hemorrhages appear black. This increases contrast revealing the path and pattern of inflamed blood vessels. Areas of the episclera where lymphocytes infection-fighting white blood cells have gathered in response to an inflammatory or immune response will appear as yellow spots under the red-free light. Fleischer ring seen in keratoconus see Chapter 5 can also be viewed satisfactorily with the red-free filter. Some instruments also have a diffuser which is a piece of frosted glass or plastic that flips in front of the illuminator. The diffuser scatters the light causing an even spread of light over the entire ocular surface. The filters are placed by flipping a lever Figure 1-6 . Patient positioning is achieved by an attached head rest unit that includes a moveable chin cup and a stationary forehead band. There may also be a strap that can be fastened behind the patient s head .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.