Đang chuẩn bị liên kết để tải về tài liệu:
Báo cáo y học: "Respiratory pulse pressure variation fails to predict fluid responsiveness in acute respiratory distress syndrome"

Đang chuẩn bị nút TẢI XUỐNG, xin hãy chờ

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Critical Care giúp cho các bạn có thêm kiến thức về ngành y học đề tài: Respiratory pulse pressure variation fails to predict fluid responsiveness in acute respiratory distress syndrome. | Lakhal et al. Critical Care 2011 15 R85 http ccforum.eom content 15 2 R85 KS CRITICAL CARE RESEARCH Open Access Respiratory pulse pressure variation fails to predict fluid responsiveness in acute respiratory distress syndrome Karim Lakhal1 Stephan Ehrmann2 Dalila Benzekri-Lefevre3 Isabelle Runge3 Annick Legras2 2 2 11 3 Pierre-Frangois Dequin Emmanuelle Mercier Michel Wolff Bernard Régnier Thierry Boulain Abstract Introduction Fluid responsiveness prediction is of utmost interest during acute respiratory distress syndrome ARDS but the performance of respiratory pulse pressure variation ArespPP has scarcely been reported. In patients with ARDS the pathophysiology of ArespPP may differ from that of healthy lungs because of low tidal volume Vt high respiratory rate decreased lung and sometimes chest wall compliance which increase alveolar and or pleural pressure. We aimed to assess ArespPP in a large ARDS population. Methods Our study population of nonarrhythmic ARDS patients without inspiratory effort were considered responders if their cardiac output increased by 10 after 500-ml volume expansion. Results Among the 65 included patients 26 responders the area under the receiver-operating curve AUC for ArespPP was 0.75 95 confidence interval CI95 0.62 to 0.85 and a best cutoff of 5 yielded positive and negative likelihood ratios of 4.8 CI95 3.6 to 6.2 and 0.32 CI95 0.1 to 0.8 respectively. Adjusting ArespPP for Vt airway driving pressure or respiratory variations in pulmonary artery occlusion pressure APAOP a surrogate for pleural pressure variations in 33 Swan-Ganz catheter carriers did not markedly improve its predictive performance. In patients with APAOP above its median value 4 mmHg AUC for ArespPP was 1 CI95 0.73 to 1 as compared with 0.79 CI95 0.52 to 0.94 otherwise P 0.07 . A 300-ml volume expansion induced a 2 mmHg increase of central venous pressure suggesting a change in cardiac preload in 40 patients but none of the 28 of 40 nonresponders responded to an .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.