TrueNet Installation Guidelines C5eT & C6T Parameter Horizontal Run Distance Patch Cable Lengths Current Standards 90 Metres Total of all patch cables less than 10 Metres Unspecified, but do not allow specific components | TrueNet Installation Guidelines C5eT C6T Parameter Current Standards TrueNet Recommendation Horizontal Run Distance 90 Metres No Change Patch Cable Lengths Total of all patch cables less than 10 Metres Total of all patch cables less than 10 Metres but only patch cables of approved lengths will be allowed. Patch Cable Source Unspecified but do not allow specific components Must be from an approved source. NO third party patch cable assembly permitted under any circumstances Twists 13mm of untwist 10mm of untwist Cable Stripping Not specified 25mm of jacket removal allowed before contact to block Bend Radii 4X s the diameter of the cable 4 times the diameter of the horizontal cable 2 times the diameter of the patch cable Bend Radii at the connection point for patch equipment cords Unspecified except for 4 times the diameter of the cable 90 degrees of change from the parallel plane of the connector device Cable Ties Not specified but recommend Velcro Velcro Tie Wraps J Hooks allowed only when placed in NON-CYCLICAL arrangement spacing Conduit No Longer than 30 metres continuous No Longer than 30 metres continuous Cable Damage Not Specified Jacket free of kinks holes and lateral cracks No water in or around jacket Cable Bundles Not Specified No More than 30 cables shall be bundled together Multiple bundle groups OK . Category Mixing Inferred Channels shall be assembled using similar NEC rated such as CM for example components throughout. All products must be approved by KRONE. Pulling Tensions 11.3 kg per 4 pair cable 13.6 kg per 4 pair cable Conduit Fill Rate Similar cable types Not specified Conduit fill of 4 pair communications type cable shall not exceed 60 fill rate. Mixing of different cable types such as communications cables and control cables not allowed KRONE Parameter Current Standards TrueNet Recommendation Block to Block Cross-Connects Specified cable Special designed jacketed crossconnect cable required part number TBD Service Loops 3 metres at closet 1 .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.