Đang chuẩn bị nút TẢI XUỐNG, xin hãy chờ
Tải xuống
The TrueNet® Category 5e system is a fully integrated family of precisely tuned components each designed to operate at optimum performance with the other. TrueNet Category 5e systems are unmatched in data throughput and are supported by the most comprehensive and thorough warranty in the industry: the TrueNet Zero Bit-Error warranty. The warranty guarantees that the structured cabling system will remain error free for a full 5 years and includes a 20-year electrical performance and free of defect warranty | TrueNet Category 5e K610 Jack to K610 Jack Patch Panel CHANNEL SPECS The TrueNet Category 5e system is a fully integrated family of precisely tuned components each designed to operate at optimum performance with the other. TrueNet Category 5e systems are unmatched in data throughput and are supported by the most comprehensive and thorough warranty in the industry the TrueNet Zero Bit-Error warranty. The warranty guarantees that the structured cabling system will remain error free for a full 5 years and includes a 20-year electrical performance and free of defect warranty. The result is a remarkably advanced and high performing end-to-end channel guaranteed beyond the typical industry requirements to maximize network throughput and minimize downtime. Numerous component options are available for versatility and flexible adaptation to meet any infrastructure requirement. Support Applications 10 100 1000 Base-T IEEE 802.3xx 1000 Base-T requires enhance DSP Electronics 4 16 Mb s Token Ring 25 155 622 Mb s ATM www.adc.com 1-952-938-8080 1-800-366-3891 Active Network Specifications IEEE Input Specification Limits 100BASE-T Spec Min. Max. Positive Amplitude 0.95V 1.05V Negative Amplitude .095V 1.05V Amplitude Symmetry 0.98 1.02 Rise Time 3 ns 5 ns Fall Time 3 ns 5 ns Rise Time Fall Time Symmetry 0 ns 0.5 ns Jitter 0 14 7 100 Meter Channel Passive Electrical Specifications CHANNEL SPECS Freq MHz Attenuation dB NEXT dB ACR dB Return Loss dB min typical min typical min typical min typical 1 3.0 1.7 60.0 80.6 57.0 66.4 17.0 31.7 4 4.5 3.3 53.6 68.9 49.1 64.9 17.0 31.7 8 6.3 4.6 48.6 63.1 42.3 60.5 17.0 31.7 10 7.1 5.2 47.0 61.2 39.9 58.6 17.0 31.7 16 9.1 6.7 43.6 57.3 34.5 53.9 17.0 31.7 20 10.2 7.5 42.0 55.4 31.8 51.2 17.0 31.7 25 11.4 8.5 40.4 53.5 28.9 48.3 16.0 30.7 31.25 12.8 9.5 38.7 51.7 25.9 45.1 15.1 29.7 62.5 18.6 14.0 33.6 45.8 14.9 33.8 12.1 26.7 100 24.0 18.2 30.1 41.9 6.0 24.8 10.0 24.7 Minimum values min represent worst case allowable in TrueNet system. Minimum