Since a secondary coolant cannot be used below its freezing point, certain ones are not applicable at the lower temperatures. Sodium chloride's eutectic freezing point of -2O0C limits its use to approximately -120C. The eutectic freezing point of calcium chloride is -530C, but achieving this limit requires such an accuracy of mixture that -4O0C is a practical low limit of usage. Water solubility in any open or semi-open system can be important. The dilution of a salt or glycol brine, or of alcohol by entering moisture, merely necessitates strengthening of the brine. . | 62.8 SYSTEM COMPONENTS 1897 Since a secondary coolant cannot be used below its freezing point certain ones are not applicable at the lower temperatures. Sodium chloride s eutectic freezing point of -20 C limits its use to approximately -12 C. The eutectic freezing point of calcium chloride is -53 C but achieving this limit requires such an accuracy of mixture that -40 C is a practical low limit of usage. Water solubility in any open or semi-open system can be important. The dilution of a salt or glycol brine or of alcohol by entering moisture merely necessitates strengthening of the brine. But for a brine that is not water-soluble such as trichloroethylene or methylene chloride precautions must be taken to prevent free water from freezing on the surfaces of the heat exchanger. This may require provision for dehydration or periodic mechanical removal of ice perhaps accompanied by replacement with fresh brine. Vapor pressure is an important consideration for coolants that will be used in open systems especially where it may be allowed to warm to room temperature between periods of operation. It may be necessary to pressurize such systems during periods of moderate temperature operation. For example at 0 C the vapor pressure of R-ll is 39.9 kPa 299 mm Hg that of a 22 solution of calcium chloride is only 0.49 kPa 3.7 mm Hg . The cost of vapor losses the toxicity of the escaping vapors and their flammability should be carefully considered in the design of the semiclosed or open system. Environmental effects are important in the consideration of trichlorofluoromethane R-ll and other chlorofluorocarbons. This is a refrigerant with a high ozone-depletion potential and halocarbon global warming potential. The environmental effect of each of the coolants should be reviewed before the use of it in a system is seriously considered. Energy requirements of brine systems may be greater because of the power required to circulate the brine and because of the extra heat-transfer .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.