TAILIEUCHUNG - Báo cáo y học: "Dose-associated changes in safety and efficacy parameters observed in a 24-week maintenance trial of olanzapine long-acting injection in patients with schizophrenia"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành y học dành cho các bạn tham khảo đề tài: Dose-associated changes in safety and efficacy parameters observed in a 24-week maintenance trial of olanzapine long-acting injection in patients with schizophrenia | Hill et al. BMC Psychiatry 2011 11 28 http 1471-244X 11 28 BMC Psychiatry RESEARCH ARTICLE Open Access Dose-associated changes in safety and efficacy parameters observed in a 24-week maintenance trial of olanzapine long-acting injection in patients with schizophrenia 1 1 2 1 1 Angela L Hill Bin Sun Jamie L Karagianis Susan B Watson David P McDonnell Abstract Background In a recently published 24-week maintenance study of olanzapine long-acting injection LAI in schizophrenia Kane et al. 2010 apparent dose-associated changes were noted in both efficacy and safety parameters. To help clinicians balance safety and efficacy when choosing a dose of olanzapine LAI we further studied these changes. Methods Outpatients with schizophrenia who had maintained stability on open-label oral olanzapine for 4 to 8 weeks were randomly assigned to low 150 mg 2 weeks N 140 medium 405 mg 4 weeks N 318 or high 300 mg 2 weeks N 141 dosages of olanzapine LAI for 24 weeks. Potential relationships between dose and several safety or efficacy measures were examined via regression analysis the Jonckheere-Terpstra test continuous data or the Cochran-Armitage test categorical data . Results Safety parameters statistically significantly related to dose were mean weight change low SD medium SD high SD kg p .024 effect size ES high vs. low dose mean change in prolactin low SD medium SD high SD gg L p .001 ES high vs. low dose fasting triglycerides change from normal at baseline to high low medium high p .001 NNT 7 high vs. low dose and fasting high-density lipoprotein cholesterol change from normal at baseline to low low medium high p .019 NNT 6 high vs. low dose . Efficacy measures significantly related to dose included Positive and Negative Syndrome Scale total score mean change low SD medium SD high SD p .01 ES high vs. low dose .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.