TAILIEUCHUNG - Membranes for Industrial Wastewater Recovery Episode 10

Tham khảo tài liệu 'membranes for industrial wastewater recovery episode 10', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | S l ỊSteiỉì des ifl ì Ỉ a ids 207 overall cost. All purification techniques previously outlined are permitted and the pinch methodology is used to target the optimal solution. As is already obvious from Section recovery of the sizing agent and recovery of alkali with simultaneous recovery of a purified water is economically very beneficial with water available at good quality at the cost price of groundwater. Looking at the proposed target 1016 ms day 1 of freshwater the water network suggested is operated at a cost price of 4S 19 lower than the base case. The target is achieved by implementing the membrane technique for treatment of the printing paste. The final effluent is discharged to the sewer system without implementing other purification processes to achieve a wastewater that can be discharged at a lower cost to the surface water. One of the How rates suggested is very small and transpires to be an internal recycle for one process. The question of whether or not the overall water flow through the process should be lowered can then be addressed. As can be seen in Table 1 for several processes multiple inlet streams should be connected. This often implies additional cost not yet accounted for by the analysis for pipework storage tanks and control. It is advisable to ignore these costs when embarking on the analysis since they make the problem too complex. When the optimum network is selected these additional costs can be added manually or can be taken into account in the program. Seem1 70 3 targeted minimum How rate when all treatments are allowed hut discharge on surface water is Imposed. The limits set for the discharge to surface waters are much stricter than those for discharge to sewer when the company is faced with these stricter values proper solutions have to be accounted for. Using the software for the case study and restricting discharges to surface water yields a daily operational cost of 6 5 51. The solution indicates that the constraints

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.