TAILIEUCHUNG - Modern Developments in X-Ray and Neutron Optics Episode 14

Tham khảo tài liệu 'modern developments in x-ray and neutron optics episode 14', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 520 V. Ac et al. Cooling Temperature Decreasing the cooling temperature is the best way to reduce mechanical deformations caused by absorption of radiation heat. The increase of the thermal conductivity of silicon Fig. together with the decreasing thermal expansion coefficient as the cooling temperature is decreased makes it possible to significantly reduce the surface deformations. These results are documented in Fig. d. The cooling by liquid nitrogen LN2 78 K can reduce the surface overheating and surface deformation by more than one order of magnitude in comparison to these effects using room temperature cooling. Cooling Channels Variations In this section we will show how it is possible to reduce variations of the surface temperature and deformation due to the reproduction of the channel arrangement by optimization of cooling channels geometry. Two possible locations of rectangular cooling channels are seen in Fig. . The cooling channels are built in the silicon target a or in a cooler block b respectively. Usually the cooler block is made from a high thermally conductive material copper . Simulations in Fig. show higher effectivity of the cooling channels made in copper block. This fact is caused by the higher thermal conductivity in the bulk of the copper cooler together with its larger surface of the cooling channels in comparison to that in the silicon target. In addition print-through of the channel geometry to the optical surface is reduced. Fig. . Cooling channels variations and corresponding simulations of surface deformation at photon energy Ep 100 eV for cooling channels in the silicon target a and cooling channels in the copper cooler block b 30 Thermal Effects under Synchrotron Radiation Power Absorption 521 Cooling Block Arrangement The next example is devoted to the revision of cooling block efficiency. Two variations of the cooling block arrangement shown in Fig. have been investigated. From .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.