TAILIEUCHUNG - Báo cáo khoa học: "Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Critical Care giúp cho các bạn có thêm kiến thức về ngành y học đề tài: Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients. | Available online http content 10 5 R135 Research Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients Anouk M Corstjens1 Jack JM Ligtenberg2 Iwan CC van der Horst3 Rob Spanjersberg2 Joline SW Lind2 Jaap E Tulleken2 John HJM Meertens2 and Jan G Zijlstra2 1 Department of Anesthesiology University Medical Center Groningen . Box NL-9700 RB Groningen The Netherlands intensive Respiratory Care Unit ICB University Medical Center Groningen . Box NL-9700 RB Groningen The Netherlands 3Department of Cardiology University Medical Center Groningen . Box NL-9700 RB Groningen The Netherlands Corresponding author Jack JM Ligtenberg Received 3 Mar 2006 Revisions requested 19 Apr 2006 Revisions received 22 Aug 2006 Accepted 18 Sep 2006 Published 18 Sep 2006 Critical Care 2006 10 R135 doi cc5048 This article is online at http content 10 5 R135 2006 Corstjens et al. licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Open Access Abstract Introduction To obtain strict glucose regulation an accurate and feasible bedside glucometry method is essential. We evaluated three different types of point-of-care glucometry in seriously ill intensive care unit ICU patients. The study was performed as a single-centre prospective observational study in a 12-bed medical ICU of a university hospital. Methods Patients with an expected ICU stay of more than 48 hours were included. Because the reference laboratory delivers glucose values after approximately 30 to 60 minutes which is too slow to use in a glucose regulation protocol and for calibration of the subcutaneous continuous glucose monitoring system CGMS CGMS .

TỪ KHÓA LIÊN QUAN
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.