TAILIEUCHUNG - User’s Manual LG Programmable Logic Controller - Chapter 9

Installation and wiring 9,1 cài đặt Cài đặt Môi trường Đơn vị này có độ tin cậy cao bất kể môi trường cài đặt của nó, nhưng hãy chắc chắn để kiểm tra sau đây cho độ tin cậy của hệ thống. 1) Môi trường yêu cầu Tránh cài đặt đơn vị này tại các địa điểm được đối tượng hoặc tiếp xúc với: (1) Nước rò rỉ và bụi. (2) Liên tục những cú sốc hoặc rung động. (3) ánh sáng mặt trời trực tiếp. (4) Dew ngưng tụ do thay đổi nhiệt độ nhanh chóng. (5) nhiệt độ cao. | Chapter 9 Installation and Wiring Chapter 9. Installation and wiring Installation Installation Environment This unit has high reliability regardless of its installation environment but be sure to check the following for system reliability. 1 Environment requirements Avoid installing this unit in locations which are subjected or exposed to 1 Water leakage and dust. 2 Continuous shocks or vibrations. 3 Direct sunlight. 4 Dew condensation due to rapid temperature change. 5 Higher or lower temperatures outside the range of 0 to 55 C 6 Relative humidity outside the range of 5 to 95 C 7 Corrosive or flammable gases 2 Precautions during installing 1 During drilling or wiring do not allow any wire scraps to enter into the PLC. 2 Install it on locations that are convenient for operation. 3 Make sure that it is not located on the same panel that high voltage equipment located. 4 Make sure that the distance from the walls of duct and external equipment be 50mm or more. 5 Be sure to be grounded to locations that have good ambient noise immunity. 3 Heat protection design of control box 1 When installing the PLC in a closed control box be sure too design heat protection of control box with consideration of the heat generated by the PLC itself and other devices. 2 It is recommended that filters or closed heat exchangers be used. 9-1 Chapter 9 Installation and Wiring The following shows the procedure for calculating the PLC system power consumption. 1 PLC system power consumption block diagram Base Unit 2 Power consumption of each part 1 Power consumption of a power supply part Approximately 70 of the power supply module current is converted into power 35 of that 65 dissipated as heat . of the output power is actually used. Wpw I5V x 5 I24V x 24 W where l5v 5VDC circuit current consumption of each part l24v 24VDC circuit average current consumption of output part with points simultaneously switched ON . Not for 24VDC power supplied from external or .

TỪ KHÓA LIÊN QUAN
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.