TAILIEUCHUNG - Báo cáo y học: "In vitro and in vivo evaluation of a new active heat moisture exchange"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Critical Care cung cấp cho các bạn kiến thức về ngành y đề tài: In vitro and in vivo evaluation of a new active heat moisture exchanger. | Available online http content 8 5 R281 Research In vitro and in vivo evaluation of a new active heat moisture exchanger Davide Chiumello1 Paolo Pelosi2 Gilbert Park3 Andrea Candiani4 Nicola Bottino1 Ezio Storelli1 Paolo Severgnini2 Dunia D Onofrio2 Luciano Gattinoni1 and Massimo Chiaranda2 Open Access Institute of Anesthesia and Critical Care University of Milan Policlinico Hospital IRCCS Milan Italy 2Department of Clinical Science University of Insubria Circolo and Fondazione Macchi Hospital Varese Italy 3Department of Intensive Care Research Addenbrooke s Hospital Cambridge United Kingdom 4Institute of Anesthesia and Critical Care University of Brescia Civili Hospital Brescia Italy Corresponding author Davide Chiumello chiumello@ Received 19 March 2004 Revisions requested 28 April 2004 Revisions received 1 9 May 2004 Accepted 09 June 2004 Published 28 June 2004 Critical Care 2004 8 R281-R288 DOI cc2904 This article is online at http content 8 5 R281 2004 Chiumello et al. licensee BioMed Central Ltd. This is an Open Access article verbatim copying and redistribution of this article are permitted in all media for any purpose provided this notice is preserved along with the article s original URL. Abstract Introduction In order to improve the efficiency of heat moisture exchangers HMEs new hybrid humidifiers active HMEs that add water and heat to HMEs have been developed. In this study we evaluated the efficiency both in vitro and in vivo of a new active HME the Performer StarMed Mirandola Italy as compared with that of existing HMEs Hygroster and Hygrobac Mallinckrodt Mirandola Italy . Methods We tested the efficiency by measuring the temperature and absolute humidity AH in vitro using a test lung ventilated at three levels of minute ventilation 5 10 and 15 l min and at two tidal volumes and 1 l and in vivo in 42 patients with acute lung injury arterial oxygen tension fractional inspired oxygen ratio 283 72 mmHg . We .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.