TAILIEUCHUNG - Báo cáo y học: "linical review: New technologies – venturing out of the intensive care unit"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Critical Care cung cấp cho các bạn kiến thức về ngành y đề tài: Clinical review: New technologies – venturing out of the intensive care unit. | Critical Care June 2005 Vol 9 No 3 Otero and Garcia Review Clinical review New technologies - venturing out of the intensive care unit Ronny Otero1 and A Joseph Garcia2 Associate Program Director Henry Ford Hospital Department of Emergency Medicine Detroit Michigan USA 2Resident Physician Departments of Emergency Medicine Internal Medicine and Critical Care Medicine Henry Ford Hospital Detroit Michigan USA Corresponding author Ronny Otero rotero1@ Published online 2 November 2004 This article is online at http content 9Z3 296 2004 BioMed Central Ltd Critical Care 2005 9 296-302 DOI cc2982 Abstract The delivery of critical care is no longer limited to the intensive care unit. The information gained by utilization of new technologies has proven beneficial in some populations. Research into earlier and more widespread use of these modalities may prove to be of even greater benefit to critically ill patients. Introduction Diagnostic and therapeutic interventions done outside the intensive care unit ICU are an integral part of the multidisciplinary continuum of critical care. Presented here is a brief review of hemodynamic monitoring ancillary studies and therapeutic modalities that are currently used or that have potential applications in the emergency department ED . Esophageal Doppler monitoring In treating critically ill patients it is often desirable to have available an objective measure of cardiac function and response to therapy. Determinations of cardiac output CO have traditionally used a pulmonary artery catheter employing the thermodilution technique in the operative suite or ICU 1-3 . The risks associated with central venous access pulmonary arterial injury embolization infection interpretation and reproducibility were previously addressed and render this modality impractical for use in the ED 2 4 5 . The esophageal Doppler monitor EDM can be used to evaluate the velocity and time at which blood travels within the descending .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.