TAILIEUCHUNG - Báo cáo y học: "Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patien"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học General Psychiatry cung cấp cho các bạn kiến thức về ngành y đề tài: Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient. | Research paper 85 Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient Massimo Bertolissi Flavio Bassi Adriana Di Silvestre and Francesco Giordano Background We evaluated the effect on the respiratory gas exchange of the 30 head-down position and the complete covering of the face by sterile drapes. These are used to cannulate the internal jugular vein and position the pulmonary artery catheter in the cardiosurgical patient. During the two manoeuvres 20 coronary patients and 10 patients with end-stage heart disease were supplied with oxygen FiO2 by a Venturi mask while 20 coronary patients breathed room air. The arterial blood samples to measure oxygen PaO2 and carbon dioxide PaCO2 tension and oxygen saturation SaO2 were analysed by a blood gas system. Results The contemporary application of the head-down position and the drapes over the face significantly increased PaO2 and SaO2 in all the patients supplied with oxygen. Without the head-down position leaving the drapes over the face did not significantly change the two parameters in the coronary patients supplied with oxygen but induced a significant increase in PaO2 and SaO2 in the patients with end-stage heart disease. In the coronary patients that were breathing room air PaO2 and SaO2 were stable throughout the study. Conclusions We conclude that the 30 head-down position and the complete covering of the face by drapes does not interfere with respiratory gas exchange and can be safely performed in coronary patients supplied with oxygen or breathing room air and in patients with end-stage heart disease supplied with oxygen FiO2 of . Address Department of Anesthesia and ICU 2 Azienda Ospedaliera Udine Italy Correspondence Massimo Bertolissi Department of Anesthesia and ICU 2 Azienda Ospedaliera Udine 33100 Italy. Fax 39 4 3255 2421 Keywords head-down position drapes covering the .

TỪ KHÓA LIÊN QUAN
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.