TAILIEUCHUNG - POWER PLANT ACOUSTICS Episode 9

Tham khảo tài liệu 'power plant acoustics episode 9', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Item 13 shows an indoor noise excess of 3 to 6 dB in the 125- to 1000-HZ octave bands. This would be rated as marginal . If the NC-25 criterion is a justified choice these noise excesses should not be permitted. A number of other factors could influence the decision. If the housing is exposed to other uncontrollable excess noise such as nearby highway activity or base aircraft activity power plant noise might not appear so noticeable. However if the base is located in a very quiet suburban or rural area with very little other noise the power plant noise will be very noticeable. If the base is located in a very hot or very cold region year-round and the windows are kept closed most of the time and if inside sources such as air conditioners or central heating and cooling systems are in near TM 5 805 9 AFM 88-20 NAVFAC ly continuous use external noise sources will not be as noisy when heard indoors. These various conditions could be used to support or justify adjustments to the NC criterion. In the present problem it is assumed that such factors have already been considered and the NC-25 selection is a valid choice. c A CNR analysis should be carried out as a means of checking or confirming the expected reaction of the housed personnel to the power plant noise. The N V manual para. 3-3c summarizes the procedure. Figure 4-24 shows the CNR grid upon which the outdoor power plant SPLs are plotted taken from Item 8 of fig. 4-23 . A noise level rank of e is obtained. 4-35 TM 5 805 9 AFM 88-20 NAVFAC OCTAVE BAND CENTER FREQUENCY Hz Figure 4-24. Outdoor power plant noise at the base housing plotted on CNR grid. 4-36 The N V table 3-4 or figure 3-4 provides a means of determining the correction number for the background noise in the area. If background noise measurements can be made at the existing base N V figure 3-4 should be used otherwise the background noise correction may be estimated by selecting the most nearly applicable conditions of N V table 3-4. .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.