TAILIEUCHUNG - Báo cáo y học: " Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học 'Respiratory Research cung cấp cho các bạn kiến thức về ngành y đề tài:" Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children. | Respiratory Research BioMed Central Research Open Access Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children K Alving 1 C Janson2 and L Nordvall3 Address Department of Physiology and Pharmacology Karolinska Institutet SE-17177 Stockholm Sweden 2Department of Medical Sciences Uppsala University Uppsala Sweden and 3Department of Women s and Children s Health Uppsala University Uppsala Sweden Email K Alving - C Janson - LNordvall - Corresponding author Published 20 April 2006 Received 20 December 2005 Respiratory Research2006 7 67 doi 1465-9921 -7-67 Accepted 20 April 2006 This article is available from http content 7 1 67 2006Alving et al licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Abstract Background Exhaled nitric oxide NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now most measurements have been done with stationary chemiluminescence-based NO analysers which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study the performance of a new electrochemical hand-held device for exhaled NO measurements NIOX MINO was compared with a standard stationary chemiluminescence unit NIOX . Methods A total of 71 subjects 6-60 years 36 males both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations 50 ml s in each device and the first approved measurement in the hand-held device were compared with regard to NO readings Bland-Altman plots .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.