TAILIEUCHUNG - HVAC and Dehumidifying Systems_1

Điều kiện thiết kế. Chọn mùa hè trong nhà và ngoài trời mùa đông và điều kiện thiết kế phù hợp với MIL-HDBK-1190. Nếu một điều kiện vi khí hậu tồn tại ở trang web, hoặc nếu xây dựng vị trí trang web không được hiển thị trong NAVFAC Xuất bản P-89, Kỹ thuật dữ liệu thời tiết, tham khảo ý kiến | Simpo PDF Merge and Split UnregisteredVersion- http Section 2 GENERAL Load and Energy Calculations Load Calculation Procedures. Refer to the ASHRAE Handbook Fundamentals for the acceptable method of performing load and energy calculations. Load Calculation Form. Except for small buildings and minor renovation less than 8000 square feet loads should be calculated using a computer program which applies one of the methods in the ASHRAE Handbook Fundamentals Chapters 25 and 26. Simplified load calculation equations are reproduced in Section 5 of this handbook. These simplified equations may be used on smaller buildings with hand calculations. Design Conditions. Select indoor and outdoor summer and winter design conditions in accordance with MIL-HDBK-1190. If a known micro-climate condition exists at the site or if building site location is not shown in NAVFAC Publication P-89 Engineering Weather Data consult the Navy design manager or project leader DM or PL for instructions. Variable Air Volume VAV Systems. For VAV systems refer to Appendix C and ASHRAE Handbook Fundamentals for the acceptable method. Outdoor Air Load a Infiltration. Use infiltration rates and the method of calculation prescribed in ASHRAE Handbook Fundamentals. b Ventilation. Use ventilation rates for IAQ prescribed in ASHRAE Standard 62 Ventilation for Acceptable Indoor Air Quality and the method of calculation included in ASHRAE Handbook Fundamentals. Energy Analysis Building Orientation. Building orientation fenestration lighting and geometry can have a profound effect on the building energy consumption system selection and zoning. Therefore the HVAC designer should consult with the architect during the early concept stage to optimize the overall design. Architectural Features. The building mass tightness of construction window treatment occupancy zoning and other characteristics can also impact the HVAC design. These

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.