TAILIEUCHUNG - MCITP Microsoft Exchange Server 2007 Messaging Design and Deployment Study Guide phần 6

, và về khả năng lưu trữ vận chuyển quy tắc cung cấp. Rất nhiều câu hỏi về kỳ thi hỏi bạn về các tùy chọn cấu hình có thể quản lý hồ sơ tin nhắn và phân loại tin nhắn. Antispam trong Exchange Server 2007, kỳ thi tập trung rất khó khăn về các tùy chọn chống thư rác Xác định chính sách và thủ tục an ninh | 404 Chapter 9 Planning a Highly Available Exchange Server 2007 Implementation When configuring the CCR cluster it is important to take into account the automatic database mount settings. You can configure the server by using the Set-MailboxServer cmdlet and setting AutoDatabaseMountDial property with one of the following values Lossless The databases will not automatically mount on the passive node until all of the logs have been copied to the passive node. If the active node goes offline the databases will not be mounted until the logs are able to be recovered from the failed node. GoodAvailability The databases will mount on the passive node as long as the copy queue length is less than or equal to two. Exchange will continue to copy the remaining logs from the failed node and attempt to mount the database. BestAvailability The databases will mount on the passive node as long as the copy queue length is less than or equal to five. Exchange will continue to copy the remaining logs from the failed node and attempt to mount the database. These settings affect the automatic mounting of the databases in a CCR cluster an administrator can choose to force a database mount in case a failover occurs with data loss. Figure shows an example of using Set-MailboxServer to modify the AutoDatabaseMountDial setting from the default of BestAvailability to Lossless. FIGURE Using Set-MailboxServer to modify the AutoDatabaseMountDial setting Because CCR uses log-file replication to provide data redundancy it is possible during a hard failover to the second node that log files are damaged on the second node. This may cause email to be lost. A feature that reduces this possibility is the transport dumpster. The transport dumpster is enabled automatically on Hub Transport servers only for CCR clusters. The Hub Transport servers will maintain a queue of recently delivered email messages to mailboxes that reside on a CCR clustered Mailbox server. If a hard failover occurs that

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.